Indirect Operational Water
Indirect Operational Water
In short: indirect operational water (W_O^ind) is water used
generating the electricity a software system consumes — at the power
plant, not at the compute facility. It follows exactly the same shape as
direct operational water — it's just measuring thirst at the power plant
instead of the data centre.
Shape: energy used × water-per-unit-of-energy-generated (the Electricity Water Intensity Factor, or EWIF) = indirect operational water.
Worked: 300 kWh × 0.9 L/kWh = 270 L. (illustrative placeholder, not a real measurement — note this is the same energy figure used in the direct operational water example, just asked a different "how thirsty" question)
Precise notation:
W_O,b^ind = E × EWIF_b (for each basis b: c = consumption, w = withdrawal)
where E is the energy consumed by the software system, in kWh, and
EWIF_b is the Electricity Water Intensity Factor for the selected basis
— litres of water consumed or withdrawn per kWh generated.
The EWIF principle
The specification is deliberately principles-based here: EWIF_b should
reflect the water consumption or withdrawal of the power plants generating
the electricity, at their point of generation — not at the facility
where the software runs, and not averaged across a broad, loosely-defined
region if a more precise figure is available. The specification requires
three things of EWIF_b:
- It matches the water accounting basis (
corw) used elsewhere in the calculation. - It corresponds to the geographic region, electricity supply, and reporting period of the energy actually consumed.
- Its temporal resolution is disclosed — if only annual data is available, that has to be said, not silently treated as equivalent to monthly data.
Everything below that principle — which datasets to use, how to handle generation types with unusual methodological wrinkles, whether to use average or marginal intensity — is genuinely implementation detail, which is exactly why it lives here rather than in the specification. See:
- EWIF — Data Sources and Implementation Guidance for the concrete datasets available today and how to choose between them.
- EWIF — Average vs. Marginal Water Intensity for an open methodological question the specification deliberately does not resolve.
- EWIF — Hydropower Classification and Treatment for the generation type the SSWG found most methodologically unsettled.
Please submit any comments you have here.